<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
<title>Génie Civil " Structures / matériaux "</title>
<link href="http://dspace.univ-tissemsilt.dz/handle/123456789/2562" rel="alternate"/>
<subtitle/>
<id>http://dspace.univ-tissemsilt.dz/handle/123456789/2562</id>
<updated>2026-11-07T20:46:04Z</updated>
<dc:date>2026-11-07T20:46:04Z</dc:date>
<entry>
<title>Conception, étude et calcul d'un bâtiment en  béton armé implanté à Tissemsilt</title>
<link href="http://dspace.univ-tissemsilt.dz/handle/123456789/3590" rel="alternate"/>
<author>
<name>BENANE, HAKIMA</name>
</author>
<id>http://dspace.univ-tissemsilt.dz/handle/123456789/3590</id>
<updated>2026-10-20T13:15:17Z</updated>
<published>2026-01-01T00:00:00Z</published>
<summary type="text">Conception, étude et calcul d'un bâtiment en  béton armé implanté à Tissemsilt
BENANE, HAKIMA
Ce mémoire présente l'étude technique, le calcul et le dimensionnement d'un bâtiment &#13;
en béton armé de type R+5, implanté à Tissemsilt.&#13;
Le travail s'articule autour des grandes étapes suivantes :&#13;
•          Présentation et conception générale : Description architecturale et structurelle de &#13;
l'ouvrage, choix des matériaux et pré-dimensionnement des éléments porteurs (poteaux, &#13;
poutres, dalles).&#13;
•          Évaluation des charges : Calcul rigoureux des charges permanentes (G) et des &#13;
surcharges d'exploitation (Q) selon les règles en vigueur, ainsi que le dimensionnement &#13;
des éléments secondaires (escaliers, acrotères, balcons, planchers).&#13;
•          Analyse sismique et contreventement : Étude dynamique et modélisation de la &#13;
structure, classification de la zone sismique de Tissemsilt et application des exigences &#13;
réglementaires (RPA) pour le système de contreventement (portiques et/ou voiles).&#13;
•          Calcul des éléments résistants et des fondations : Vérification de la résistance et du &#13;
ferraillage des éléments principaux selon le BAEL et le RPA, ainsi que l'étude &#13;
géotechnique et le dimensionnement des fondations (semelles ou radier).&#13;
•          Modélisation numérique : Utilisation du logiciel ETABS pour l'analyse &#13;
tridimensionnelle, la vérification des déplacements (effet &#119875;−Δ) et l'optimisation du &#13;
comportement dynamique de la structure.
</summary>
<dc:date>2026-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Étude d’un bâtiment à étages multiples de moyenne hauteur</title>
<link href="http://dspace.univ-tissemsilt.dz/handle/123456789/3587" rel="alternate"/>
<author>
<name>Sahouane, Soufiane</name>
</author>
<author>
<name>Sekkou, Yahia</name>
</author>
<id>http://dspace.univ-tissemsilt.dz/handle/123456789/3587</id>
<updated>2026-10-20T09:52:58Z</updated>
<published>2026-01-01T00:00:00Z</published>
<summary type="text">Étude d’un bâtiment à étages multiples de moyenne hauteur
Sahouane, Soufiane; Sekkou, Yahia
L'objet de ce projet consiste en l'étude et le dimensionnement d'un bâtiment à usage &#13;
d'habitation de type R+4, contreventé par un système mixte composé de portiques et de voiles &#13;
en béton armé. Le bâtiment est implanté à Théniet El Had, wilaya de Tissemsilt, classée en &#13;
zone de sismicité moyenne (Zone III) selon les Règles Parasismiques Algériennes (RPA &#13;
2024).&#13;
Le  pré-dimensionnement  des  éléments  porteurs  a  été  effectué  conformément  aux &#13;
prescriptions  du  règlement  BAEL  91  modifié,  ainsi  qu'aux  exigences  du  RPA  2024, &#13;
garantissant ainsi la sécurité structurelle et la conformité réglementaire de l'ouvrage.&#13;
L'analyse sismique de la structure a été réalisée à l'aide du logiciel de calcul ETABS, &#13;
permettant la modélisation tridimensionnelle et l'évaluation du comportement dynamique du &#13;
bâtiment sous l'effet des actions sismiques, conformément aux prescriptions du RPA 2024.&#13;
Le calcul des sollicitations — moments fléchissants, efforts tranchants et efforts normaux &#13;
— dans les éléments porteurs principaux (poteaux, poutres et voiles) a été mené à l'aide du &#13;
logiciel ETABS. Le dimensionnement et le ferraillage de ces éléments, ainsi que des éléments &#13;
secondaires (dalles, escaliers), ont été effectués manuellement conformément aux règlements &#13;
en vigueur.&#13;
L'infrastructure du bâtiment est constituée de fondations superficielles, à savoir des &#13;
semelles isolées et des semelles filantes, choisies en fonction des charges transmises par la &#13;
superstructure et des caractéristiques géotechniques du sol d'assise.
</summary>
<dc:date>2026-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Valorization of marble waste in mortar partial replacement of ciment</title>
<link href="http://dspace.univ-tissemsilt.dz/handle/123456789/3586" rel="alternate"/>
<author>
<name>ELAKAF, Nadjet</name>
</author>
<id>http://dspace.univ-tissemsilt.dz/handle/123456789/3586</id>
<updated>2026-10-20T09:47:21Z</updated>
<published>2026-01-01T00:00:00Z</published>
<summary type="text">Valorization of marble waste in mortar partial replacement of ciment
ELAKAF, Nadjet
Industrial marble processing activities generate massive volumes of discarded fragments, causing &#13;
severe  environmental  challenges  when  left  unmanaged.  Upcycling  these  residues  into &#13;
construction materials offers an innovative solution that reduces waste and lowers the carbon &#13;
footprint of building components. This dissertation investigates the incorporation of thermally &#13;
activated marble powder (TAMP) into cement mortars and evaluates its effects on mechanical &#13;
and fresh-state performance. The marble waste was manually collected, cleaned, ground, and &#13;
thermally activated at 900°C for one hour. &#13;
The experimental program was carried out using a standard Portland-limestone cement (CEM &#13;
II/A-L 42.5 N, NA 442) mixed with local sand. Mortar mixtures were prepared with varying &#13;
TAMP contents (0%, 5%, 10%, and 15% by weight of cement). Fresh properties were analyzed &#13;
through consistency and Vicat setting time tests. Compressive strength was assessed at 3, 7, and &#13;
28 days using prismatic specimens, while flexural tensile strength and durability metrics (water &#13;
absorption and mass loss) were measured at later ages. &#13;
The  results  showed  that  the  inclusion  of  5%  TAMP  maintained  excellent  mechanical &#13;
performance,  retaining  98%  of  the  28-day  control  compressive  strength.  While  higher &#13;
substitution dosages (10% and 15%) experienced an early-age strength drop at 3 days due to &#13;
binder dilution, their 28-day compressive values recovered past a structurally viable 31 MPa. &#13;
Furthermore, the 10% and 15% mixes achieved a 3.9% and 3.5% increase in flexural strength, &#13;
respectively, due to the micro-filler effect that densified the matrix and reduced capillary water &#13;
absorption to 6.27%. In contrast, the 15% mix showed a higher mass loss under environmental &#13;
exposure, highlighting performance limits at elevated dosages. &#13;
This  study  demonstrates  the  technical  feasibility  of  recycling  marble  fragments  in  mortar, &#13;
offering  a  dual  benefit:  environmental  protection  through  waste  valorization  and  optimized &#13;
material performance.
</summary>
<dc:date>2026-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Étude d’un Bâtiment en RDC+4 Etages en Béton Armé Selon le Règlement Parasismique Algérien RPA 2024</title>
<link href="http://dspace.univ-tissemsilt.dz/handle/123456789/3584" rel="alternate"/>
<author>
<name>SAHOUANE, Farouk</name>
</author>
<author>
<name>BELKACEMI, Mahmoud Abdelkrime</name>
</author>
<id>http://dspace.univ-tissemsilt.dz/handle/123456789/3584</id>
<updated>2026-10-20T09:41:20Z</updated>
<published>2026-01-01T00:00:00Z</published>
<summary type="text">Étude d’un Bâtiment en RDC+4 Etages en Béton Armé Selon le Règlement Parasismique Algérien RPA 2024
SAHOUANE, Farouk; BELKACEMI, Mahmoud Abdelkrime
Ce mémoire de fin d’études porte sur la conception et le dimensionnement d’un bâtiment &#13;
d’habitation collective de 100 logements publics, d’une hauteur de 15,96 m, implanté &#13;
dans la wilaya de Tissemsilt. L’étude est menée conformément aux recommandations du &#13;
Règlement Parasismique Algérien (RPA 2024) applicables à la Zone II.&#13;
Elle comprend le prédimensionnement et le calcul des principaux éléments structuraux &#13;
ainsi que des éléments secondaires (escaliers et planchers à corps creux), selon le BAEL &#13;
et le RPA 2024, en mettant en évidence les nouvelles exigences de confinement et de &#13;
ductilité pour améliorer la performance sismique de l’ouvrage.&#13;
Le contreventement est assuré par un système portiques voiles en béton armé garantissant &#13;
une rigidité suffisante face aux actions sismiques. En raison des charges de l’ouvrage et &#13;
de la capacité portante faible du sol (S3), un radier général a été retenu afin d’assurer une &#13;
répartition uniforme des contraintes et de limiter les tassements différentiels.
</summary>
<dc:date>2026-01-01T00:00:00Z</dc:date>
</entry>
</feed>
